MarinaQuadro Plus
Think of it as insurance for your luxury furniture. It comes with fire-retardant technology which can delay spreading of fire. Its E emission compliance, bacteria and fungi proof qualities make it one of the safest plywoods ever. Made with thicker face veneer, MQ Plus is additionally pressed for extra strength and precision. It comes with a 100% money-back guarantee, against manufacturing defects.
Thickness (MM)
Sizes (MM)
Application
SR NO. | Tests Method | ISI requirements | Observed Values |
---|---|---|---|
1 | Dimension Squareness | Length :+ 6 mm Width :+ 3 mm Thicknes : +/- 5% Max : 0.20% |
Length- 2442 mm Width- 1221 mm Thickness- 19 mm Squareness - 0.13% |
2 | Moisture content | Moisture content should not be less than 5% and not more than 15% | 8.3% |
3 | Glue Adhesion in Dry State (a) Glue Shear Strength |
Average: 1350 N Minimum Individual: Avg.: 1100 N |
1401 N 1110 N |
(b) Adhesion of Plies | Bond shall show minimum Pass Standard, Poor or Excellent |
Satisfactory | |
4 | Water Resistance Test (After 72 hours boiling in water) (a) Glue Shear Strength |
Average : 1000 N Minimum Individual : 800 N |
1099 N 1002 N |
(b) Adhesion of Plies | Bond shall show minimum Pass Standard, Poor or Excellent |
Satisfactory | |
5 | Tensile Strength (a) Parallel to the grain direction |
Should not be less than 42.0 N/mm² |
57.93 N/mm² |
(b)Prependicular to the grain direction | Should not be less than 25.0 N/mm² | 40.12 N/mm² | |
(c) Sum of both the direction | Should not bf less than 84.5 N/mm² | 98.05 N/mm² | |
6 | Mycological Test (a) Glue Shear Strength |
Average 1000 N Minimum lndividual : 800 N |
1310 N 1260 N |
(b) Adhesion of Plies | Test piece shall show no appreciation signs of separation at the edges of the Veneers | No appreciation sign of separation at the edges of the veneers |
|
7 | Modulus of Elasticity (a) Along the grains of the face Veneer |
Average: 7500 N/mm² Min. lndividual-6700 N/mm² |
7820 N/mm² 7200 N/mm² |
b)Across the grains of the face Veener | Average: 4000 N/mm² Min. lndividual-3600 N/mm² |
4750 N/mm² 3840 N/mm² |
|
8 | Modulus of Rupture (a) Along the grains of the face Veneer |
Average: 50 N/mm² Min. lndividual-45 N/mm² |
54 N/mm² 48 N/mm² |
(b) Across the grains of the face Veener | Average: 30 N/mm² Min. lndividual-27 |
36 N/mm² 30 N/mm² |
|
9 | Horizontal Rate of burning | The result of the test shall be considered satisfactory if taking the worst test results into account, the horizontal burning rate is not more than 100 mm / min or if the flame extinguishes before reaching the last measuring point | Satisfactory |
10 | Vertical rate of burning | The result of the test described in Annex B shall be considered satisfactory if taking the worst test results into account the vertical burning rate is not more than 100 mm / min | Satisfactory |